Description
Flush before you inject. Crack Flushing Agent cleans cracks and construction joints in concrete before you inject polyurethane resin. It flushes out dirt and dissolves lime and calcite deposits, so the resin bonds to clean concrete.
Where it's used: potable water tanks, hydro dams, tunnel linings and storage tanks. It works on wet, damp or dry cracks, including ones with seepage or flowing leaks.
How to use it:
- Drill the injection holes and set the packers.
- Add one 1.65 kg bottle of concentrate to about 15 L of clean water (always add the concentrate to the water, never the reverse) and stir for 1 to 2 minutes.
- Inject the solution with a single-component pump until the dirt is flushed out and the flow is steady.
- Within 10 minutes, flush the crack with plenty of clean water.
- Inject the resin with separate equipment, not the pump you used for flushing.
- Clean the flushing pump with clean water right away.
Handle with care: the concentrate is a strong acid. It causes severe skin burns and eye damage and can corrode metal. Wear chemical gloves and eye and face protection, and keep the work area well ventilated, with mechanical ventilation in confined spaces. Don't let it freeze.
Use it with: a pump kept for water and flushing only, such as a second Impact X 410 pump or a Lever Gun. Never a pump that also runs resin.
Size: 1.65 kg bottle, enough for about 15 L of flushing solution. Stores for up to 5 years.
For trained professionals with the proper equipment. Read the Safety Data Sheet before use.